found Gateway multiple

Multiple Gateways Found

Kuka · KR C4 DeviceNet

Hva betyr found Gateway multiple ?

More than one identical gateway module has been detected on the bus. The system supports a maximum of one master and one slave gateway, and this redundancy causes a DeviceNet master configuration error (Message 4429).

Vanlige årsaker

  • Multiple Gateway devices detected on the network when only one is expected.
  • Incorrect network configuration leading to duplicate device addresses.
  • Faulty device installation or network cabling causing reflection.
  • Software error in device discovery or management.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Remove the superfluous gateway module from the bus.

  2. 2

    Reconfigure the bus to reflect the correct number of gateways.