Overvoltage PMx

KPS Intermediate Circuit Overvoltage During Operation

Kuka · KR C2 Robot Controller

Hva betyr Overvoltage PMx ?

An overvoltage condition has been detected in the intermediate circuit of the KPS module (PMx) during operation. This can be caused by excessively high mains voltage or a defective ballast switch not dissipating regenerative energy.

Vanlige årsaker

  • Intermediate circuit voltage exceeds the safe limit during operation.
  • Regenerative braking feedback too high without sufficient load.
  • Power supply fluctuations.
  • Faulty capacitor bank in the intermediate circuit.
  • Overvoltage protection device failure.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Measure the incoming mains voltage at the KPS input terminals. If it exceeds specifications, identify and rectify the source of the high voltage.

  2. 2

    If the mains voltage is within specifications, the ballast switch inside the KPS module may be defective; exchange the KPS module.