HEAT SINK TEMPERATURE Ax

Axis Heat Sink Overtemperature

Kuka · KR C2 Robot Controller

Hva betyr HEAT SINK TEMPERATURE Ax ?

An overtemperature condition has been detected on the heat sink of the servo drive module for the specified axis (Ax). This indicates inadequate cooling or excessive load on the axis.

Vanlige årsaker

  • Ambient temperature in the cabinet is too high.
  • Insufficient cooling for the drive's heat sink (blocked vents, fan failure).
  • Drive operating at peak load for extended periods.
  • Oversized motor or drive operating inefficiently.
  • Faulty temperature sensor on the heat sink (P6-01).

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the cabinet cooling circuit and fans for proper operation and airflow.

  2. 2

    Reduce the load on the affected axis by decreasing the Override (OVR) setting in the robot program.

  3. 3

    Reduce the velocity for the affected axis using the `$VEL_AXIS` parameter.

  4. 4

    Reduce the acceleration for the affected axis using the `$ACC_AXIS` parameter.