Drives error Ax no.: 80

KSD EEPROM Communication Error (Power Unit)

Kuka · KR C2 Robot Controller

Hva betyr Drives error Ax no.: 80 ?

A communication error has occurred with the EEPROM in the power unit of the servo drive module for the specified axis (Ax). This suggests an issue with data storage or retrieval within the KSD's power unit.

Vanlige årsaker

  • Communication error between the KSD power unit and its EEPROM.
  • Faulty EEPROM chip on the power unit.
  • Intermittent connection issues to the EEPROM.
  • EEPROM data corruption.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the KSD module for visible damage or loose connections.

  2. 2

    Restart the controller.

  3. 3

    If the error persists after restart, exchange the KSD module.