Cabinet temperature too high PMx

KPS Interior Overtemperature

Kuka · KR C2 Robot Controller

Hva betyr Cabinet temperature too high PMx ?

An overtemperature condition has been detected inside the KPS module (PMx). This indicates that the cabinet ventilation is not functioning correctly, leading to an elevated interior temperature affecting the KPS.

Vanlige årsaker

  • Ambient temperature within the control cabinet is excessive.
  • Cabinet cooling system (fans, filters) is inadequate or malfunctioning.
  • External heat sources impacting the cabinet temperature.
  • High power dissipation from internal components.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the cabinet ventilation system for proper operation and sufficient airflow.

  2. 2

    Verify that cabinet air filters are clean and not obstructed.

Se alle koder i denne manualen (58)
Verifisert teknisk data. Sist oppdatert: March 2026