91

EEr-Trip (External error, short-circuit braking requested by controller)

Kuka · KR C2 Robot Controller

Hva betyr 91 ?

This fault indicates an external error that has triggered a request for short-circuit braking from the controller (KSDs). This means a fault condition outside the drive itself has been detected by the controller, leading it to initiate an emergency stop, highlighting a safety or process-critical issue that requires external investigation.

Vanlige årsaker

  • External controller command for short-circuit braking.
  • Signal loss from an external safety device.
  • Faulty wiring in the external control interface.
  • Over-speed condition detected by external unit.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Review the controller's diagnostic messages for the specific external error triggering this fault.

  2. 2

    Verify the status of safety inputs and other external signals connected to the controller or associated with the machine.

  3. 3

    Isolate external devices connected to the controller one by one to identify the source of the external error.

Se alle koder i denne manualen (58)