50

OH-Trip (Overtemperature, heat sink)

Kuka · KR C2 Robot Controller

Hva betyr 50 ?

This fault indicates an overtemperature condition detected at the heat sink of the device. This implies insufficient heat dissipation, potentially due to blocked airflow, a faulty cooling fan, or excessive ambient temperature, which can lead to thermal shutdown and component damage.

Vanlige årsaker

  • OH-Trip: Overtemperature detected on heatsink (P1-11).
  • Insufficient cooling or ventilation for the drive.
  • Excessive ambient temperature in the control cabinet.
  • Drive operating at high load continuously.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify cooling fan operation by observing its rotation and airflow direction.

  2. 2

    Measure ambient temperature around the device enclosure — ensure it is within specified operating limits.

  3. 3

    Clear any dust or debris from the heat sink fins and cooling air vents using compressed air.

Se alle koder i denne manualen (58)