Oversetter...
-14

Path File Access Error

Kuka · KR C2 Robot Controller

Hva betyr -14 ?

The OR_PATH_REPLAY() function failed to open the specified path file. This could be due to file corruption, incorrect permissions, or an underlying issue with the storage system on the Compute Box.

Vanlige årsaker

  • An error occurred while trying to read from or write to a path file.
  • Permissions issue preventing access to the path data file.
  • File is locked by another process.
  • Disk read/write error for the path file.
  • Incomplete or corrupted file transfer for the path data.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the Compute Box for any active write protection or file system errors that might hinder file access.

  2. 2

    Attempt to restart the robot controller and the Compute Box to reset file system handles and clear temporary access issues.

  3. 3

    If the issue persists, consider re-uploading or re-recording the path to ensure file integrity.

Se alle koder i denne manualen (58)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kuka -14 — Reparasjon: Path File Access Error teknisk guide | ErrorLib