106

HO6 trip (Checksum error in the power unit device set)

Kuka · KR C2 Robot Controller

Hva betyr 106 ?

This fault indicates a checksum error within the power unit device set (KSDs). This implies corruption or inconsistency in the power unit's stored device configuration data, which can lead to incorrect power stage operation or system instability.

Vanlige årsaker

  • Checksum error in power unit device configuration data.
  • Corrupted configuration parameters in the power unit.
  • Memory fault within the power unit's internal storage.
  • Improperly loaded device set data.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Re-upload the power unit device set configuration from a known good backup to the device.

  2. 2

    Perform a power cycle of the power unit to reinitialize its memory and check for persistent error.