JF
Mastering Error
Kuka · KK53Y Servo Motor
Hva betyr JF ?
The JF signal indicates a mastering error, meaning at least one axis of the manipulator is not mastered. When this signal is '0', it signifies an active mastering error, which consequently deactivates space monitoring for safety. A '1' state indicates no error and active space monitoring.
Vanlige årsaker
- General mastering error indicating a fault in the control or synchronization logic.
- Communication disruption or data inconsistency within the mastering system.
- Internal software error within the mastering controller.
- Configuration error in critical mastering parameters.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Perform the complete mastering procedure for all manipulator axes according to the robot's operating instructions.
- 2
Verify that the 'JF' signal output transitions to '1' after successful mastering, confirming the error is cleared and space monitoring is reactivated.