STOP 0

Safety Stop 0

Kuka · Industrial Robots Use & Programming

Hva betyr STOP 0 ?

A Safety STOP 0 has been triggered and executed by the safety controller. This is an immediate and uncontrolled stop where the safety controller de-energizes all robot drives and applies the brakes without a deceleration ramp. It is the highest priority safety stop.

Vanlige årsaker

  • Detection of movement during a safe operational stop (standstill monitoring violation).
  • Activation of an external safety device (e.g., safety mat, laser scanner, photoelectric curtain).
  • Internal fault detected within the safety controller hardware or software.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Identify the specific safety device or condition that triggered the STOP 0 (e.g., open safety gate, tripped safety mat).

  2. 2

    Clear the triggering condition (e.g., close safety gate, remove obstruction from safety mat).

  3. 3

    Acknowledge any pending safety messages on the smartPAD.

  4. 4

    Re-activate robot drives through the appropriate controller interface.

Se alle koder i denne manualen (6)
Verifisert teknisk data. Sist oppdatert: March 2026