Under-speeding
Kone · Frequency Inverter
Hva betyr 24 ?
This fault is recorded if the speed feedback falls below the permitted speed threshold for 0.5 seconds. The permitted speed is calculated as (Reference Speed - 0.25m/s) for reference speeds under 1.0 m/s, or (0.5 x Reference Speed) for reference speeds over 1.0 m/s.
Vanlige årsaker
- Malfunction of the speed feedback sensor, providing an inaccurate or excessively low speed reading.
- Insufficient motor torque or power output from the drive, preventing the lift from reaching the commanded speed.
- Excessive mechanical load on the lift, causing it to run slower than the reference speed.
- Incorrect setting of motor or drive parameters affecting speed regulation.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify the calibration and functionality of the speed feedback device (encoder) and check its signal integrity.
- 2
Inspect the motor for any mechanical issues or damage that could impede its performance.
- 3
Check the drive unit for proper operation, ensuring it provides sufficient current and voltage to the motor.
- 4
Measure the current drawn by the motor to identify potential overload conditions or inadequate power delivery.
- 5
Review all speed-related parameters in the control system, including acceleration/deceleration rates and reference speeds.