Oversetter...
72

Power Failure

Kone · Electric Traction Elevators

Hva betyr 72 ?

The KONE LCE W/KDM elevator system has experienced a loss of its primary power supply. The elevator is now operating on a backup power source (e.g., Emergency Rescue Device (ERD) or battery) or performing a controlled shutdown for passenger evacuation.

Vanlige årsaker

  • Interruption of the main incoming AC power supply to the elevator control panel.
  • Tripped circuit breaker (e.g., F3 on page 2) or blown fuse within the elevator's power distribution.
  • Failure of the uninterruptible power supply (UPS) or emergency power system components.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Direct passengers to safely exit the elevator car once the doors open at the evacuation floor.

  2. 2

    Check the status of the main power supply to the LCE W/KDM control panel and verify associated circuit breakers (e.g., Mainline Disconnect Switch, Lighting Supply Disconnect Switch 115V/15A on page 6) are engaged.

  3. 3

    Measure incoming AC line voltage at the control panel to confirm power presence and stability.

  4. 4

    Inspect the F3 fuse (0.65A) on the 366: FSP RS485 REPEATER board (page 2) for continuity.

Se alle koder i denne manualen (13)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Kone Electric Traction Elevators