Brake control

Kone · CMXC-022 Frequency Control Upgrade Kit

Hva betyr 71 ?

An error has been detected within the brake control circuit of the R&M Materials Handling Frequency Converter, indicating a malfunction that could prevent the brake from engaging or disengaging properly. This poses a significant safety risk, especially in hoist applications.

Vanlige årsaker

  • Error detected in the brake control circuit

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check and repair the brake control circuit wiring

  2. 2

    Measure the brake coil resistance and compare to specifications

  3. 3

    Replace the brake if its resistance is outside specifications

  4. 4

    If the problem recurs, replace the inverter

Se alle koder i denne manualen (40)
Verifisert teknisk data. Sist oppdatert: March 2026