63

Stall

Kone · CMXC-022 Frequency Control Upgrade Kit

Hva betyr 63 ?

The motor is not running, indicating a stall condition detected by the R&M Materials Handling Frequency Converter. This can be due to a mechanical failure in the gear system or a missing speed signal from the encoder connected to ENC1A, preventing the drive from detecting motor movement.

Vanlige årsaker

  • Motor not running (stall condition)
  • Mechanical failure, e.g., in the gear system
  • Missing speed signal in ENC1A

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check or replace the motor

  2. 2

    Check and repair the motor wiring

  3. 3

    Check hoist operation without any load applied

  4. 4

    Check or replace the speed sensor connected to ENC1A

Se alle koder i denne manualen (40)