Oversetter...
F8130
Firmware of option 2 of safety technology defective
Indramat · Indradrive
Hva betyr F8130 ?
The firmware for the safety technology option module 2 is detected as defective or corrupted. Similar to F8129, this prevents safety functions from operating and results in drive shutdown for safety compliance.
Vanlige årsaker
- Corrupted firmware in safety option module 2.
- Incorrect firmware version loaded for the specific safety option module.
- Hardware defect within the safety option module 2.
- Communication error with the safety option module.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Cycle power to the IndraDrive.
- 2
Verify the correct firmware version for safety option module 2 is installed and re-flash it if necessary.
- 3
Check the physical seating and connections of safety option module 2 within the IndraDrive.
- 4
Ensure the safety configuration parameters are valid and consistent.
- 5
If the error persists, the safety option module 2 itself may be defective and require replacement.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Indramat Indradrive