F8118

Invalid power section/firmware combination

Indramat · Indradrive

Hva betyr F8118 ?

The firmware loaded on the IndraDrive is not compatible with the detected power section hardware. This mismatch can occur after firmware updates, hardware changes, or if an incorrect firmware package was installed, preventing the drive from operating safely or correctly.

Vanlige årsaker

  • Firmware update was performed with an incorrect version for the specific power section.
  • Power section module was replaced with one that is incompatible with the existing firmware.
  • Incorrect drive variant (e.g., voltage class, current rating) detected by the firmware.
  • Corruption of firmware or hardware identification data.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify the part numbers and versions of the IndraDrive power section and the installed firmware.

  2. 2

    Ensure that the firmware version is specifically designed and certified for the exact power section model installed.

  3. 3

    If an incompatible firmware was installed, download and flash the correct firmware version.

  4. 4

    If a power section was replaced, ensure it is compatible with the drive's control unit and existing firmware.

  5. 5

    Consult the IndraDrive documentation for compatible firmware and hardware combinations.