Velocity threshold exceeded
Indramat · Indradrive
Hva betyr F7013 ?
The motor's actual velocity has exceeded a safety-related velocity threshold. This fault is part of safe motion monitoring (e.g., Safely Limited Speed) and is triggered when the axis moves faster than permitted under certain safety conditions, potentially leading to a hazardous situation.
Vanlige årsaker
- Uncontrolled increase in motor speed.
- Incorrectly configured safety-related velocity threshold parameter (e.g., S-0-0XXX Safe Velocity Threshold).
- Faulty speed feedback from the encoder providing incorrect actual velocity.
- External forces driving the motor.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify the configured safety-related velocity threshold parameter in the IndraDrive against the safety requirements.
- 2
Check the motor encoder for correct operation, secure mounting, and reliable speed signal output.
- 3
Review the motion control program for any commands that might cause the motor to exceed the threshold.
- 4
Inspect for external mechanical forces that could be driving the motor beyond the commanded speed.
- 5
Re-tune the speed control loop to ensure stable velocity control and prevent overshooting of commanded speeds.