F6034

Emergency-Stop activated

Indramat · Indradrive

Hva betyr F6034 ?

The external emergency stop circuit connected to the IndraDrive has been activated, commanding an immediate and controlled stop of the motor. This is a safety feature designed to bring the machine to a safe state in an emergency.

Vanlige årsaker

  • Emergency stop button pressed.
  • Fault in the emergency stop wiring (e.g., broken wire, short to ground).
  • Associated safety device (e.g., light curtain, safety gate) triggered.
  • Faulty emergency stop relay or safety module.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify that no emergency stop buttons or safety devices (e.g., light curtains, safety gates, pull cords) are activated.

  2. 2

    Inspect the emergency stop circuit wiring for any breaks, loose connections, or short circuits.

  3. 3

    Reset the emergency stop circuit and the drive after confirming the cause of activation.

  4. 4

    Check the status of any external safety relays or modules integrated into the emergency stop chain.

  5. 5

    Review the emergency stop logic in the safety controller to ensure proper functionality.