E248

Interpolation Acceleration Equals Zero

Indramat · ECODRIVE Controller

Hva betyr E248 ?

This warning indicates that the currently effective acceleration value in the position command value is zero. This can occur if a selected positioning block has been parameterized with an acceleration of a=0. Operating with zero acceleration in interpolation modes can lead to unexpected motion profiles or lack of movement.

Vanlige årsaker

  • The acceleration value in the position command or a selected positioning block is set to 0.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Identify the active positioning block or command value source.

  2. 2

    Enter a sensible acceleration value greater than 0 for the relevant parameter in the positioning block or command.

  3. 3

    Verify that the motion profile configuration ensures a non-zero acceleration for interpolated movements.