Oversetter...
E225

Motor overload

Indramat · CLM01.3-M Flying Cutoff Control

Hva betyr E225 ?

The drive reduces the maximum possible motor current to protect the motor from destruction. This warning is issued when the motor peak current (S-0-0109) is reduced due to current limitation. If a current greater than 2.2 times the motor current at standstill (S-0-0111) flows, the current reduction begins. With 4-fold motor current at standstill, reduction starts after 400 ms; with 5-fold, it starts earlier; with 3-fold, later. This reduction also affects P-0-4045 (Active permanent current).

Vanlige årsaker

  • Excessive mechanical load on the motor, causing it to draw high current.
  • Incorrect motor parameters (e.g., S-0-0111, S-0-0109, P-0-4045) not matching the connected motor or application requirements in the Indramat DIAX04 SSE-03VRS drive controller.
  • Motor or driven machinery binding or experiencing high friction.
  • Drive controller current limits set too low for the application's peak demands.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Inspect the mechanical system driven by the motor for any binding, blockage, or excessive friction that could cause high current draw.

  2. 2

    Verify the motor parameters S-0-0111 (Motor current at standstill) and S-0-0109 (Motor peak current) in the Indramat DIAX04 SSE-03VRS drive controller against the motor nameplate data and application requirements.

  3. 3

    Monitor the motor's actual current draw during operation and compare it against its nominal and peak ratings to confirm an overload condition.

  4. 4

    Adjust process parameters or mechanical settings to reduce the load on the motor if it is consistently operating at or near its current limits.

  5. 5

    Evaluate the P-0-4045 (Active permanent current) parameter setting to ensure it is appropriate for the application.

Se alle koder i denne manualen (31)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Indramat CLM01.3-M Flying Cutoff Control