Emergency-Stop
Indramat · DIAX 04
Hva betyr F634 ?
The DIAX04 SSE-03VRS drive has received an Emergency-Stop command, leading to an immediate and safe shutdown of the controlled axis. This fault is triggered by the activation of a safety-rated E-Stop circuit, which is critical for preventing injury or damage in hazardous situations. This typically implies an external E-Stop input.
Vanlige årsaker
- An external Emergency-Stop button was pressed or activated by an operator.
- A safety light curtain, safety gate, or other safety device connected to the DIAX04 SSE-03VRS safety input was triggered.
- Fault in the external safety circuit (e.g., wiring short, sensor failure) that falsely activated the E-Stop input.
- Incorrect wiring or configuration of the E-Stop input to the DIAX04 SSE-03VRS drive.
- Internal fault within the DIAX04 SSE-03VRS drive's safety input monitoring system.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Identify and reset all activated Emergency-Stop buttons and external safety devices in the system.
- 2
Inspect the entire E-Stop safety circuit, including wiring, buttons, and safety relays, for damage, loose connections, or incorrect operation.
- 3
Verify the status of the E-Stop input on the DIAX04 SSE-03VRS drive through its diagnostics to ensure the signal is clear.
- 4
Ensure the E-Stop wiring connected to the DIAX04 SSE-03VRS is correctly terminated and free from shorts or open circuits.
- 5
If the E-Stop was not intentionally activated, systematically test each component of the external safety chain to isolate the faulty component or wiring section.