Phase switching without ready signal
Indramat · DIAX 04
Hva betyr F406 ?
The DIAX04 SSE-03VRS drive attempted a communication phase switch (e.g., Sercos) without receiving the necessary 'ready' signal from the master controller or another network component. This indicates a synchronization or handshake failure, preventing the network from achieving a stable operational state. The drive faults to maintain communication integrity.
Vanlige årsaker
- Master controller failed to send the 'ready' signal at the appropriate time during phase switching.
- Delay or loss of the 'ready' signal due to communication link issues (e.g., damaged cable, network congestion).
- DIAX04 SSE-03VRS drive's communication interface is faulty, not detecting the 'ready' signal correctly.
- Incorrect timing parameters or synchronization settings (e.g., S-0-0014) between the master and slave.
- Firmware incompatibility or bug affecting communication handshakes.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify the communication configuration and timing parameters on both the master controller and the DIAX04 SSE-03VRS drive, focusing on phase switching and ready signals.
- 2
Inspect the communication cable (e.g., Sercos fiber optic) for any physical damage or poor connections.
- 3
Check the diagnostic status of the master controller to confirm it is sending the 'ready' signal as expected.
- 4
Ensure proper termination and absence of excessive electromagnetic interference on the communication network.
- 5
Perform a full power cycle of the entire DIAX04 SSE-03VRS system and the master controller. If the fault persists, consider a faulty communication interface.