SRG speed too high
Heidenhain · TNC CNC Controllers
Hva betyr 231-E008 ?
This error indicates that the Safe Reduced Rotational Velocity (SRG) limit has been exceeded, or that the Heidenhain TNC CNC Controller failed to achieve a standstill during the Safe Controlled Stop (SBH) operating mode. This is a critical safety violation, as the machine is operating at an unsafe speed or has not stopped as commanded by a safety function, posing a risk of injury or damage.
Vanlige årsaker
- The actual motor speed has exceeded the configured Safe Reduced Rotational Velocity (SRG) threshold.
- The drive or motor failed to achieve standstill within the specified time during an active Safe Controlled Stop (SBH) command.
- Malfunction in the speed monitoring system or the motor encoder feedback, leading to incorrect speed detection.
- Incorrect parameterization of the SRG or SBH safety functions within the controller or safety module.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify the actual motor speed using diagnostic tools on the Heidenhain TNC CNC Controller and compare it against the configured SRG limit parameter in the safety controller.
- 2
Check the functionality of the motor encoder and its wiring for any damage, loose connections, or signal interference that could lead to inaccurate speed feedback.
- 3
Review the parameters related to Safe Reduced Rotational Velocity (SRG) and Safe Controlled Stop (SBH) in the CNC controller and safety module; ensure they are correctly configured according to the machine's design and safety requirements.
- 4
Perform a controlled test of the SBH function, monitoring the motor's deceleration and verifying that it reaches standstill within the specified time.
- 5
If the issue persists after verifying parameters and feedback, consult a Heidenhain service agency for further diagnostics on the safety module or drive system.