Drive lock on spindle, SS2 reaction active
Heidenhain · TNC CNC Controllers
Hva betyr 231-A097 ?
This error indicates that a spindle drive was locked. This occurs when an attempt was made to switch on a spindle drive while the guard door was open, AND a Stop 2 (SS2) reaction was active for the spindle, or due to an internal software error.
Vanlige årsaker
- Attempt to switch on a spindle drive while the guard door was open and a Stop 2 (SS2) reaction was active for the spindle.
- Safety function SS2 is still active or in an abnormal state for the spindle.
- Internal software error.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Ensure the guard door is closed before attempting to switch on the spindle drive.
- 2
Verify that the Stop 2 (SS2) reaction for the spindle has fully completed and reset before attempting to enable the drive.
- 3
Check the software version of the controller and update it if a known issue related to SS2 management exists.
- 4
Review the safety program logic to ensure proper handling of spindle drive enable requests during and after an SS2 condition.