Drive lock through safety software (CC)
Heidenhain · TNC CNC Controllers
Hva betyr 231-A090 ?
This error indicates that a drive (or multiple drives) has been locked by the safety software of the CC (Controller) module. This occurs when an emergency stop is active (due to -ES.B or -NE2 signal) and an attempt is made to switch on a drive, or due to an internal software error.
Vanlige årsaker
- Emergency stop activated (by CC) via -ES.B or -NE2 signal.
- Attempt to switch on a drive while the system is in an 'emergency stop' condition.
- Internal software error within the CC module.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify the status of the emergency stop circuit and the -ES.B or -NE2 signals. Ensure the E-stop is reset.
- 2
Check the wiring of the emergency stop circuit to the CC module for integrity, shorts, or breaks.
- 3
Confirm that all safety doors and interlocks are closed and secured, as they might trigger an emergency stop condition.
- 4
Verify the software version of the CC module and update it if a known bug fix is available.