5647 E014
Error in CC switch-off test
Heidenhain · NC Control
Hva betyr 5647 E014 ?
During a CC switch-off test, the CC switch-off signal '-N0' failed to switch correctly on both CC (Controller Control) units. This suggests a hardware defect or an issue with the connection between the controller boards.
Vanlige årsaker
- CC switch-off signal: -N0 does not switch on both CCs.
- Hardware defective.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Power cycle the NC control to reset the system and re-attempt the CC switch-off test.
- 2
Check the communication and wiring connections between both controller boards (CCs) for damage, looseness, or improper termination.
- 3
Inspect both controller boards for any visible damage, signs of overheating, or component failures.
- 4
Verify that the -N0 signal path is correctly implemented and functioning across both CC units, confirming signal integrity.
Verifisert teknisk data. Sist oppdatert: March 2026