Oversetter...
2929 E002

Status NE1/NE2 not equal

Heidenhain · NC Control

Hva betyr 2929 E002 ?

The status of NE1 and NE2 inputs is not equal, likely due to incorrect connection of the NE2 input or an internal software error. This indicates a discrepancy in critical safety or feedback signals.

Vanlige årsaker

  • NE2 input incorrectly connected.
  • Internal software error.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the wiring of the NE1 and NE2 inputs for the affected component, ensuring NE2 is connected correctly according to the machine's electrical schematics.

  2. 2

    Inspect the physical connections for looseness, damage, or improper termination at the input terminals.

  3. 3

    Verify the software version of the NC control for any known issues or specific requirements related to NE1/NE2 input handling.

  4. 4

    Perform continuity checks on the NE1/NE2 signal lines and their corresponding safety module or input card to ensure signal integrity.

Se alle koder i denne manualen (58)
Verifisert teknisk data. Sist oppdatert: March 2026