Oversetter...
2207 F280

Motor %.1s: speed not equal to Imax

Heidenhain · NC Control

Hva betyr 2207 F280 ?

The current motor speed for the displayed axis does not equal the expected speed at Imax (peak current). This could indicate a motor struggling to reach commanded speed, potentially due to excessive load, or an incorrect direction of rotation.

Vanlige årsaker

  • Current motor speed does not equal the expected at Imax.
  • Perhaps the direction of rotation is wrong.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify the motor's direction of rotation by jogging the axis manually; if incorrect, reverse two motor phases or adjust the drive parameter for motor direction.

  2. 2

    Check for mechanical binding, excessive load, or increased friction on the axis that could prevent the motor from reaching expected speeds at peak current.

  3. 3

    Review the motor encoder feedback for accuracy and ensure its parameters (e.g., line count, resolution) are correctly configured in the NC control.

  4. 4

    Inspect the motor and drive parameters related to maximum current (Imax) and maximum speed (N-MAX) to ensure they are consistent and accurate for the application.

Se alle koder i denne manualen (58)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder