No brake line test was conducted %d
Heidenhain · NC Control
Hva betyr 13649 F200 ?
The MC (Motion Control) unit did not conduct a motor brake line test, even though it is required according to parameter settings, or the test duration exceeded 10 seconds. This indicates a potential safety critical fault with the motor brake system.
Vanlige årsaker
- MC runs no test of the motor brake line although it is necessary according to parameter settings.
- The call for testing a brake line lasts longer than 10 seconds.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify the parameters related to motor brake testing are correctly configured, ensuring the test is enabled when necessary.
- 2
Check the motor brake wiring and connections for any damage, looseness, or incorrect installation, including the brake supply voltage.
- 3
Inspect the motor brake unit itself for proper mechanical function, signs of wear, or sticking.
- 4
Monitor the execution time of the brake line test; if it consistently exceeds 10 seconds, investigate potential delays in brake activation or release mechanisms.
- 5
Ensure the drive system is providing adequate voltage and current to reliably activate and release the brake.