13581 E012

N0 status test to active

Heidenhain · NC Control

Hva betyr 13581 E012 ?

The measured status of the '-N0' signal is at a 'high' level, and the '-N0' signal fails to change to the 'active' ('low' level) status. This indicates a potential software error or a hardware defect.

Vanlige årsaker

  • The measured status of the "-N0" signal is "high" level.
  • The "-N0" signal does not change to the "active" ("low" level) status.
  • Software error.
  • Hardware defective.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Power cycle the NC control to attempt a reset of the safety circuit and signal states.

  2. 2

    Check the wiring and connections related to the -N0 signal path for any damage, loose terminals, or improper shielding.

  3. 3

    Inspect the controller board for any visible damage, burnt components, or signs of hardware malfunction.

  4. 4

    Verify the safety software configuration and parameters related to the -N0 signal's active state and its expected behavior.

  5. 5

    If available, use a multimeter or oscilloscope to monitor the -N0 signal level and confirm it remains high when expected to transition to low.