Oversetter...
Backup power overload

Backup power overload

Fronius · Symo Advanced

Hva betyr Backup power overload ?

This status code indicates that the inverter has stopped operating in backup power mode due to excessive electrical loads connected to the PV Point. The inverter has a maximum continuous output of 1560 W (120V at 13A) and an overload capacity of 35% for a duration of 5 seconds, depending on the current PV module power.

Vanlige årsaker

  • Connected electrical loads at the PV Point (OP) terminal exceed the inverter's continuous power rating of 1560 W.
  • Transient load surges (e.g., from motor startups) exceed the inverter's short-term overload capacity of 35% for more than 5 seconds.
  • Insufficient energy generation from the PV modules to support the connected loads at the PV Point.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Measure the total power consumption of all loads connected to the PV Point (OP) terminal and compare it against the inverter's continuous output rating of 1560 W.

  2. 2

    Disconnect non-essential loads from the PV Point to reduce the overall power demand below 1560 W.

  3. 3

    Evaluate if any loads connected to the PV Point cause high inrush currents (e.g., fridges, freezers) that exceed the 35% overload capacity for longer than 5 seconds. Consider connecting these loads to a different circuit if possible.

  4. 4

    Verify that the PV modules are generating sufficient power to support the connected loads, especially during peak demand.

Se alle koder i denne manualen (41)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder