Sensor Fault
Fronius · Symo Advanced
Hva betyr 701 ?
This status code indicates a fault with an external sensor connected to the Fronius Primo GEN24 208-240 inverter, such as a Smart Meter or a temperature sensor. This can be caused by wiring issues, a defective sensor, or incorrect sensor configuration.
Vanlige årsaker
- Issue with the wiring to the external sensor, such as a loose connection, break, or short circuit.
- The external sensor itself is defective and providing incorrect or no data.
- Incorrect configuration settings for the sensor within the inverter's parameters (e.g., sensor type, address).
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Check the wiring connecting the external sensor to the inverter for continuity, proper termination, and secure connections.
- 2
Verify the sensor configuration settings in the inverter's user interface, ensuring they match the installed sensor type and parameters.
- 3
If possible, test the sensor's functionality independently or temporarily replace it with a known good sensor to isolate the fault.
- 4
De-energize the inverter (switch off AC and DC disconnects), wait for 5 minutes, then re-energize to reset. If the message persists, the sensor may require replacement.