Oversetter...
604

Battery Temperature

Fronius · Symo Advanced

Hva betyr 604 ?

This status code indicates that the battery temperature is outside its permitted operating range for the Fronius Primo GEN24 208-240 inverter. This can be caused by the battery operating in excessively hot or cold environments, or by a malfunction of the battery's internal temperature sensor.

Vanlige årsaker

  • The battery is operating in an ambient environment where the temperature is too high.
  • The battery is operating in an ambient environment where the temperature is too low.
  • A fault with the battery's internal temperature sensor, providing inaccurate readings.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Measure the ambient temperature at the battery's installation location and ensure it is within the battery manufacturer's specified operating temperature range.

  2. 2

    Ensure proper ventilation around the battery system to facilitate heat exchange.

  3. 3

    If the ambient temperature is outside the specified range, relocate the battery system to a more suitable environment.

  4. 4

    De-energize the inverter and battery system, wait for 5 minutes, then re-energize. If the message persists, the battery system may require service.

Se alle koder i denne manualen (41)
Verifisert teknisk data. Sist oppdatert: March 2026