1177
Backup Power Restart Attempts Exceeded
Fronius · Symo Advanced
Hva betyr 1177 ?
Service message 1177 is triggered when the inverter has reached its maximum configured number of automated restart attempts in backup power mode. This indicates that the system failed to re-establish backup power operation after multiple shutdowns.
Vanlige årsaker
- Repeated failures to restart backup power mode due to persistent issues.
- The configured 'Backup power restart attempts' limit has been met.
- Underlying issues preventing stable backup power operation (e.g., undervoltage, overvoltage, short circuit, etc.).
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Manually acknowledge service message 1177 on the inverter's user interface to clear the fault.
- 2
Check the 'Backup power restart attempts' parameter (1-10) to understand the configured limit.
- 3
Investigate other potential backup power related faults such as 'Backup power undervoltage protection time U<', 'Backup power surge protec- tion time U>', or 'Backup power short circuit switch-off time' that might be causing repeated shutdowns.
Verifisert teknisk data. Sist oppdatert: March 2026