1177

Backup Power Restart Attempts Exceeded

Fronius · Symo Advanced

Hva betyr 1177 ?

Service message 1177 is triggered when the inverter has reached its maximum configured number of automated restart attempts in backup power mode. This indicates that the system failed to re-establish backup power operation after multiple shutdowns.

Vanlige årsaker

  • Repeated failures to restart backup power mode due to persistent issues.
  • The configured 'Backup power restart attempts' limit has been met.
  • Underlying issues preventing stable backup power operation (e.g., undervoltage, overvoltage, short circuit, etc.).

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Manually acknowledge service message 1177 on the inverter's user interface to clear the fault.

  2. 2

    Check the 'Backup power restart attempts' parameter (1-10) to understand the configured limit.

  3. 3

    Investigate other potential backup power related faults such as 'Backup power undervoltage protection time U<', 'Backup power surge protec- tion time U>', or 'Backup power short circuit switch-off time' that might be causing repeated shutdowns.