Inverter: FSSB communication error (COP10B)

Fanuc · Series 30i CNC

Hva betyr U ?

A communication error has occurred on the FSSB (FANUC Serial Servo Bus) via the COP10B connector. This indicates a problem with the COP10B connector or cable, the SVM, or the CNC unit, preventing proper data exchange for servo control.

Vanlige årsaker

  • Connector or cable (COP10B) failure.
  • SVM failure.
  • CNC failure.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Inspect the COP10B connector for secure connection and damage.

  2. 2

    Check the COP10B cable for continuity and shorts.

  3. 3

    Verify termination settings on the FSSB bus.

  4. 4

    Check CNC diagnostic screens for further FSSB-related errors.