Oversetter...
8.
Inverter: IPM alarm (OH) (L axis)
Fanuc · Series 30i CNC
Hva betyr 8. ?
An Intelligent Power Module (IPM) overheat alarm has occurred for the L-axis. This indicates the IPM for the L-axis is operating at an excessively high temperature. This typically results from the motor being used under harsh conditions (e.g., heavy load) or a high ambient temperature around the SVM.
Vanlige årsaker
- The motor is being used under a harsh condition.
- The ambient temperature is high.
- SVM failure.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify the motor load for the L-axis is within its rated specifications.
- 2
Measure the ambient temperature around the SVM.
- 3
Verify adequate airflow to the SVM's heat sink and cooling components for the L-axis.
Verifisert teknisk data. Sist oppdatert: March 2026
Relaterte feilkoder
Kilde: Fanuc Series 30i CNC