Fanuc · Series 30i/31i/32i-MODEL B Plus

Hva betyr H ?

This alarm indicates that the temperature of the regenerative resistor in the α i PSR unit has risen abnormally high. This can be caused by the resistor not being detected, an undersized resistor, excessive regenerative power, or a stopped cooling fan.

Vanlige årsaker

  • Regenerative resistance not detected.
  • Insufficient regenerative resistance specification.
  • Excessive regenerative power due to high acceleration/deceleration frequency.
  • Regenerative resistor cooling fan has stopped.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the wiring for the regenerative resistance.

  2. 2

    Review the specification for the regenerative resistance to ensure it is adequate for the application.

  3. 3

    Reduce the frequency at which acceleration/deceleration occurs to manage regenerative power.

  4. 4

    Check to see if the regenerative resistor cooling fan has stopped and replace it if necessary.

Se alle koder i denne manualen (38)
Verifisert teknisk data. Sist oppdatert: March 2026