Inverter: cooling fan stopped of the radiator
Fanuc · Series 30i/31i/32i-MODEL B Plus
Hva betyr F ?
The cooling fan responsible for the inverter's radiator has stopped functioning. Possible causes include the fan not running, a defective fan motor connector or cable, or a failure within the Servo Amplifier. A non-operational radiator fan can lead to critical overheating.
Vanlige årsaker
- Fan not running
- Fan motor connector or cable defective
- Servo Amplifier failure
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Inspect the radiator cooling fan for obstructions, debris, or physical damage.
- 2
Verify the fan motor connector and cable for secure connection and electrical continuity.
- 3
If the fan and its cabling are confirmed functional, replace the Servo Amplifier.