Oversetter...
369

DATA TRANS. ERROR(INT)

Fanuc · Series 30i/31i/32i-MODEL B Plus

Hva betyr 369 ?

This internal alarm signals a communication data error, primarily caused by noise affecting the data transmission. Unstable position data from the Pulsecoder can lead to incorrect axis control or unexpected machine behavior.

Vanlige årsaker

  • Noise causing unstable position data from the Pulsecoder.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check CNC diagnosis information No.356 (Built-in detector) and No.357 (Separate detector) for incremented values, which indicate noise effects. The value is cleared when the CNC unit is powered off.

Se alle koder i denne manualen (38)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Fanuc Series 30i/31i/32i-MODEL B Plus