410

Excessive Position Error Amount During Stop

Fanuc · Series 20 CNC

Hva betyr 410 ?

This alarm indicates that when the servo axis is commanded to stop, its actual position deviates from the commanded position by an amount exceeding a predefined tolerance (position error limit). This suggests an inability to hold position or an unexpected disturbance while stationary.

Vanlige årsaker

  • External force acting on the axis while stopped.
  • Mechanical binding or excessive backlash in the axis.
  • Insufficient holding torque from the servo motor or faulty brake (if equipped).
  • Incorrect position gain (Parameter 1825) or stopping parameters for the servo.
  • Faulty encoder or feedback system.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check for any external forces, such as tooling weight or workpiece sag, that might be moving the axis while it is supposed to be stopped.

  2. 2

    Inspect the mechanical system for backlash, play, or binding that allows movement when the motor is stopped.

  3. 3

    Verify the servo motor's holding torque and the functionality of any mechanical brake, adjusting or repairing as necessary.

  4. 4

    Review and adjust servo parameters related to position gain (e.g., Parameter 1825) and position error limits (e.g., Parameter 1829), ensuring they are appropriate for the application.

  5. 5

    Monitor encoder feedback for stability and accuracy when the axis is stationary, checking for noise or erratic signals.

Se alle koder i denne manualen (43)