DS1448

Scale Area Exceeded

Fanuc · Series 0i-MODEL F Plus Parameter

Hva betyr DS1448 ?

This alarm is issued if parameter settings for the scale area on the affected axis cause it to extend across the scale zero point or base point. This indicates an invalid configuration for the linear scale with absolute address reference marks or an absolute address zero point. Parameters 1883 and 1884 are typically involved in defining this area.

Vanlige årsaker

  • The actual load on the axis has exceeded the configured maximum allowable limit in parameter P1-67.
  • The position command has exceeded the programmable limit set in parameter P1-68 for the specified axis.
  • A sudden external force or collision has caused the axis to move beyond its safe operational range.
  • The load sensor feedback is inaccurate or malfunctioning, leading to a false 'scale area exceeded' condition.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Check the values of parameter No. 1883 and parameter No. 1884 for the affected axis.

  2. 2

    Adjust parameter settings to ensure the defined scale area does not extend beyond the physical scale zero point or base point.