Oversetter...
405

Reference Position Return Error

Fanuc · Alpha i series AC Servo Motor

Hva betyr 405 ?

Reference position return could not be executed correctly. This alarm can be triggered if parameter No. 032 (CMR) is configured with a value within the range of 4 to 96.

Vanlige årsaker

  • Reference position return procedure not completed successfully.
  • Parameter No. 032 (CMR) is set to a value between 4 and 96.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Re-execute the reference position return procedure.

  2. 2

    If parameter No. 032 (CMR) is set between 4 and 96, set bit 4 (N405) of parameter No. 001 to '1' to prevent this alarm.

Se alle koder i denne manualen (60)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Fanuc Alpha i series AC Servo Motor