090

Reference Position Setting Error

Fanuc · Alpha i series AC Servo Motor

Hva betyr 090 ?

Reference position setting could not be executed normally. This indicates a failure in establishing the machine's reference point.

Vanlige årsaker

  • Failure to establish the reference position during the setting procedure.
  • Servo position error is not exceeding 128 when moving in jog mode for reference position return.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Move the tool in the direction of reference position return in jog mode at a speed that causes the servo position error to exceed 128. Then, specify another reference position setting.