SP1226

Framing Error (CNC-Spindle, 30i)

Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters

Hva betyr SP1226 ?

A framing error occurred in communication between the CNC and the serial spindle amplifier for Series 30i. This typically indicates a mismatch in communication protocol or timing parameters.

Vanlige årsaker

  • Data framing error in serial communication between CNC and spindle amplifier (30i).
  • Incorrect start or stop bits configuration in serial communication settings.
  • Data bits misalignment due to incorrect baud rate or bit timing.
  • A faulty UART on either the CNC or the spindle amplifier.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify serial communication parameters (baud rate, data bits, stop bits, parity) match on both ends.

  2. 2

    Inspect the serial data signal integrity at the terminal block.

  3. 3

    Ensure the serial connector is clean and properly seated.

  4. 4

    Test the serial port functionality by using a loopback connector.