SP0996
Incorrect Spindle/Motor Assignment (15i)
Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters
Hva betyr SP0996 ?
The assignment of spindles and spindle motors for Series 15i is incorrect. This can lead to improper control or system conflicts due to mismatched configuration.
Vanlige årsaker
- Incorrect assignment of spindle drive numbers in parameters.
- Mismatched motor identification signals between CNC and amplifier.
- Faulty encoder feedback from the spindle motor.
- Configuration error in parameters defining motor polarity or feedback type.
- Software logic error in the CNC's spindle assignment module.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify parameter P2-01 (and related spindle assignment parameters) match the physical connections.
- 2
Check that encoder feedback signals (e.g., A, B, Z phases) are correctly connected to the amplifier.
- 3
Inspect the encoder cable for continuity and signal integrity.
- 4
Perform a motor identification test via the CNC menu.
- 5
Ensure the motor nameplate data matches the configured parameters in the CNC.