Oversetter...
SP0031

Motor Lock Alarm

Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters

Hva betyr SP0031 ?

The spindle motor is detected to be in a locked or stalled condition, preventing rotation. This can be due to excessive mechanical load, a brake issue, or a fault in the motor itself.

Vanlige årsaker

  • Spindle motor is mechanically jammed or seized.
  • Excessive cutting forces are preventing rotation.
  • Amplifier command signal is not reaching the motor.
  • Low voltage supply to the motor windings.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Manually rotate spindle shaft to check for free movement.

  2. 2

    Measure motor terminal voltages (U, V, W) when commanded to run.

  3. 3

    Inspect spindle bearing for seizure or damage.

  4. 4

    Verify amplifier output stage is functional (e.g., by checking for abnormal heat).

Se alle koder i denne manualen (60)
Verifisert teknisk data. Sist oppdatert: March 2026

Relaterte feilkoder

Kilde: Fanuc AC Spindle Motor Alpha i-Beta i Series Parameters