APS: Operand address %d too high for address range %d.

Bosch Rexroth · Motion Control

Hva betyr 894 ?

The operand address (identified by %d) provided to the APS (Application Processing System) exceeds its corresponding valid operand range (identified by %d) within the ICL (Internal Command Language). This is a PLC error, indicating an incorrect memory or resource address assignment.

Vanlige årsaker

  • Operand address exceeding the corresponding operand range within the ICL.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Change the operand address in MACODA to fall within the valid range.

  2. 2

    Restart the PLC program (using a programming device) or initiate a new system startup (without a programming device).