F3151

Safety command for system halt incorrect

Bosch Rexroth · IndraDrive MPx02

Hva betyr F3151 ?

This non-fatal safety error indicates that the command received by the IndraDrive MPx02 to initiate a safety-related system halt is incorrect or invalid. This implies a failure in the safe shutdown process, which is critical for machine safety.

Vanlige årsaker

  • Incorrect sequence or timing of the safety halt command from the master controller or safety PLC.
  • Mismatch between the expected and received safety halt command (e.g., wrong bit pattern or value).
  • Communication error preventing the correct safety halt command from reaching the IndraDrive MPx02.
  • Incorrect parameterization of the safety halt logic.
  • Failure of internal safety logic to correctly process the halt command.

Reparasjonssteg & Sjekkliste

Klikk på steg for å spore fremgangen.

  1. 1

    Verify the exact sequence, timing, and value of the safety system halt command being sent by the master controller or safety PLC.

  2. 2

    Check safety parameters in the IndraDrive MPx02 related to safety halt logic and response.

  3. 3

    Inspect the communication link between the master controller and the IndraDrive MPx02 for errors.

  4. 4

    Ensure that any external safety devices triggering the halt command are functioning correctly.

  5. 5

    If the error persists despite correct external commands, a power cycle of the IndraDrive MPx02 may be necessary to clear internal logic states.

Se alle koder i denne manualen (99)
Verifisert teknisk data. Sist oppdatert: March 2026