Error when checking acknowledgment signal
Bosch Rexroth · IndraDrive MPx02
Hva betyr F3131 ?
This non-fatal safety error occurs on the IndraDrive MPx02 when an expected acknowledgment signal for a safety function is either missing, incorrect, or not received within the specified timeframe. This prevents the safety function from proceeding or resetting, as the system cannot confirm its proper execution or reset state.
Vanlige årsaker
- Acknowledgment push button or external safety device malfunction.
- Wiring issue in the acknowledgment circuit (e.g., open circuit, short circuit).
- Incorrect parameterization of the acknowledgment monitoring time or logic.
- Communication fault preventing the acknowledgment signal from reaching the IndraDrive MPx02.
- Operator failed to provide the acknowledgment signal after a safety event.
Reparasjonssteg & Sjekkliste
Klikk på steg for å spore fremgangen.
- 1
Verify that the acknowledgment push button or external safety device is functioning correctly and is not stuck or damaged.
- 2
Inspect the wiring of the acknowledgment signal path to the IndraDrive MPx02 for loose connections, damage, or improper termination.
- 3
Measure the voltage at the acknowledgment input terminal on the IndraDrive MPx02 to confirm signal presence upon activation.
- 4
Check safety parameters in the IndraDrive MPx02 related to acknowledgment monitoring, specifically timing and logic settings.
- 5
Ensure the operator is following the correct procedure for acknowledging safety faults or system states.